LORENTZ Solar Trackers
LORENTZ Tracking Systems allow high additional energy yields. Dependent on location, increases of up to 40% can be achieved. The control system, serving worldwide for more than 10 years, and the robust mechanics of ETATRACK Tracking Systems guarantee untroubled operation, even under toughest climatic conditions.
ETATRACK 600
|
ETATRACK 1000-30
|
ETATRACK 1500-A
|
ETATRACK H-1500
|
ETATRACK 2000-A
|
ETATRACK 2500-A-30
|
ETATRACK Active 2000-A
Module surface of 220 ft², max power installed: c. 3.6 kWp, second axis: manually adjustable stepwise 0 – 45°
Characteristics
- total module surface up to c. 220 ft²
- no failure-prone light sensor
- no unnecessary tracking movements
- low power consumption(c. 1.5 kWh/year)
- statics according to German and European standards
- high reliability and life-expectancy
- maintenance-free
- cost-efficient tracking system
Application
- single-axis tracking system for PV modules*
- additional energy yield of up to 40 % compared to fixed installations
Design
Tracking Unit
- single-axis tracking system
- angle of second axis adjustable 0 – 45° in steps of 5°
- elevation East-West: 90°
- module surface up to c. 220 ft²
- max. dimensions of mounted frames (supportive area, installation area PV modules): width: 11’ 6”, height: 19’ 4”, up to four rows of PV modules in upright position
- frame and pole: steel, hot-dip Zn-coated
- screw set: steel, Zn-coated
- module clamps made of stainless steel for mounting the PV modules using the holes in the module frame, incl. M6 stainless steel screw kits
- suitable for high wind speeds: statics according to German and European standards
- low energy consumption c. 1.5 kWh/year
- maintenance-free
- electronics incl. battery in plastic housing
- supply voltage: 12 V DC (nominal voltage) up to 50 Voc (open-circuit voltage), by one of the tracked modules**
- stepwise tracking, depending on the daily sunshine duration (length of day)
- South position in darkness
- synchronisation of multiple units possible
- standby mode in periods of low irradiation***
- DC linear drive
- maintenance-free
- concrete foundation with steel reinforcement (min. 140 ft³)
- ambient temperature range: –13 °F to +122 °F
- daily average ambient humidity: max. 80 %
- air salinity: max. 2 µg/m3, or distance from coast: min. 1 km
- altitude: –1,300 ft to +10,000 ft MSL
- for detailed description of ambient conditions for safe operation, cf. installation manual
- designs for other conditions on request
** for safe operation in specific system designs, an additional small module might be necessary, cf. installation manual
*** for safe operation, cf. installation manual